| C_SC_TA_1 |
Single command with time tag CP56Time2a |
IEC 60870-5-104 |
| C_DC_TA_1 |
Double command with time tag CP56Time2a |
IEC 60870-5-104 |
| C_RC_TA_1 |
Regulating step command with time tag CP56Time2a |
IEC 60870-5-104 |
| C_SE_TA_1 |
Set-point command with time tag CP56Time2a, normalized value |
IEC 60870-5-104 |
| C_SE_TB_1 |
Set-point command with time tag CP56Time2a, scaled value |
IEC 60870-5-104 |
| C_SE_TC_1 |
Set-point command with time tag CP56Time2a, short floating point number |
IEC 60870-5-104 |
| C_BO_TA_1 |
Bitstring of 32 bit with time tag CP56Timea2a |
IEC 60870-5-104 |
| C_TS_TA_1 |
Test command with time tag CP56Time2a |
IEC 60870-5-104 |
| F_SC_NB_1 |
Request archive file |
IEC 60870-5-104 |
| M_SP_NA_1 |
Single-point information |
IEC 60870-5-101 |
| M_SP_TA_1 |
Single-point information with time tag |
IEC 60870-5-101 |
| M_DP_NA_1 |
Double-point information |
IEC 60870-5-101 |
| M_DP_TA_1 |
Double-point information with time tag |
IEC 60870-5-101 |
| M_ST_NA_1 |
Step position information |
IEC 60870-5-101 |
| M_ST_TA_1 |
Step position information with time tag |
IEC 60870-5-101 |
| M_BO_NA_1 |
Bitstring of 32 bit |
IEC 60870-5-101 |
| M_BO_TA_1 |
Bitstring of 32 bit with time tag |
IEC 60870-5-101 |
| M_ME_NA_1 |
Measured value, normalized value |
IEC 60870-5-101 |
| M_ME_TA_1 |
Measured value, normalized value with time tag |
IEC 60870-5-101 |
| M_ME_NB_1 |
Measured value, scaled value |
IEC 60870-5-101 |
| M_ME_TB_1 |
Measured value, scaled value with time tag |
IEC 60870-5-101 |
| M_ME_NC_1 |
Measured value, short floating point number |
IEC 60870-5-101 |
| M_ME_TC_1 |
Measured value, short floating point number with time tag |
IEC 60870-5-101 |
| M_IT_NA_1 |
Integrated totals |
IEC 60870-5-101 |
| M_IT_TA_1 |
Integrated totals with time tag |
IEC 60870-5-101 |
| M_EP_TA_1 |
Event of protection equipment with time tag |
IEC 60870-5-101 |
| M_EP_TB_1 |
Packed start events of protection equipment with time tag |
IEC 60870-5-101 |
| M_EP_TC_1 |
Packed output circuit information of protection equipment with time tag |
IEC 60870-5-101 |
| M_PS_NA_1 |
Packed single-point information with status change detection |
IEC 60870-5-101 |
| M_ME_ND_1 |
Measured value, normalized value without quality descriptor |
IEC 60870-5-101 |
| M_SP_TB_1 |
Single-point information with time tag CP56Time2a |
IEC 60870-5-101 |
| M_DP_TB_1 |
Double-point information with time tag CP56Time2a |
IEC 60870-5-101 |
| M_ST_TB_1 |
Step position information with time tag CP56Time2a |
IEC 60870-5-101 |
| M_BO_TB_1 |
Bitstring of 32 bits with time tag CP56Time2a |
IEC 60870-5-101 |
| M_ME_TD_1 |
Measured value, normalized value with time tag CP56Time2a |
IEC 60870-5-101 |
| M_ME_TE_1 |
Measured value, scaled value with time tag CP56Time2a |
IEC 60870-5-101 |
| M_ME_TF_1 |
Measured value, short floating point number with time tag CP56Time2a |
IEC 60870-5-101 |
| M_IT_TB_1 |
Integrated totals with time tag CP56Time2a |
IEC 60870-5-101 |
| M_EP_TD_1 |
Event of protection equipment with time tag CP56Time2a |
IEC 60870-5-101 |
| M_EP_TE_1 |
Packed start events of protection equipment with time tag CP56Time2a |
IEC 60870-5-101 |
| M_EP_TF_1 |
Packed output circuit information of protection equipment with time tag CP56Time2a |
IEC 60870-5-101 |
| C_SC_NA_1 |
Single command |
IEC 60870-5-101 |
| C_DC_NA_1 |
Double command |
IEC 60870-5-101 |
| C_RC_NA_1 |
Regulating step command |
IEC 60870-5-101 |
| C_SE_NA_1 |
Set point command, normalized value |
IEC 60870-5-101 |
| C_SE_NB_1 |
Set point command, scaled value |
IEC 60870-5-101 |
| C_SE_NC_1 |
Set point command, short floating point number |
IEC 60870-5-101 |
| C_BO_NA_1 |
Bitstring of 32 bits |
IEC 60870-5-101 |
| M_EI_NA_1 |
End of initialization |
IEC 60870-5-101 |
| C_IC_NA_1 |
Interrogation command |
IEC 60870-5-101 |
| C_CI_NA_1 |
Counter interrogation command |
IEC 60870-5-101 |
| C_RD_NA_1 |
Read command |
IEC 60870-5-101 |
| C_CS_NA_1 |
Clock synchronization command |
IEC 60870-5-101 |
| C_TS_NA_1 |
Test command |
IEC 60870-5-101 |
| C_RP_NA_1 |
Reset process command |
IEC 60870-5-101 |
| C_CD_NA_1 |
Delay acquisition command |
IEC 60870-5-101 |
| P_ME_NA_1 |
Parameter of measured value, normalized value |
IEC 60870-5-101 |
| P_ME_NB_1 |
Parameter of measured value, scaled value |
IEC 60870-5-101 |
| P_ME_NC_1 |
Parameter of measured value, short floating point number |
IEC 60870-5-101 |
| P_AC_NA_1 |
Parameter activation |
IEC 60870-5-101 |
| F_FR_NA_1 |
File ready |
IEC 60870-5-101 |
| F_SR_NA_1 |
Section ready |
IEC 60870-5-101 |
| F_SC_NA_1 |
Call directory, select file, call file, call section |
IEC 60870-5-101 |
| F_LS_NA_1 |
Last section, last segment |
IEC 60870-5-101 |
| F_AF_NA_1 |
Ack file, ack section |
IEC 60870-5-101 |
| F_SG_NA_1 |
Segment |
IEC 60870-5-101 |
| F_DR_TA_1 |
Directory |
IEC 60870-5-101 |